Ultrasonic Flow Meter (PIOX R721)
Inline Process Refractometer PIOX R721 – Chemical Design Variant
The concentration analysis of liquid media is one of the most critical parameters for a proper process and quality control within the Chemical Industry.
By measuring the refractive index, concentration levels of many media consumed or created within the chemical and textile fiber industry, such as solvents, acids, caustics as well as other intermediate and end products, can accurately be monitored and a continuous quality control be assured.
The chemical design variant of the process refractometer PIOX R721 R is offered as a fully stainless steel design variant with all wetted materials made out of grade 316 Ti / 1.4571 steel.
When dealing with highly corrosive media, such as hydrochloric, strong sulfuric or hydroflouric acid, PIOX R is also available as a special carbon reinforced PTFE design variant offering an unrivalled corrosion resistance, long term stability and reliability in such harsh environments.
Both designs are highly durable against any corrosive and toxic media due to their internal FFKM gaskets, the media and scratch resistant sapphire optics as well as the complete separation of the sensorhead from the electronics compartment.
Being ATEX Zone 0/1 certified and available with long and short sensorheads that can be integrated into the process via DIN / ANSI flange or the proprietary FLEXIM flow cell, PIOX R721 is the ideal process analytical technology for a wide array of liquid media within the chemical industry.
Advantages
• Patented transmitted light measurement principle - offering completely drift free, precise and long term stable measurements
• Highly accurate optical process technology making costly laboratory tests obsolete
• No flow velocity needed - as known from conventional technologies
• Independent in regard to gas bubbles and turbidity as well as the media‘s viscosity
• Internal self diagnostic tools for predictive and low maintenance efforts
Advantages
• Oil & Gas
- Underground Gas Storage & Processing
- Upstream / Offshore Solutions
• Chemical Industry
- Base & Intermediate Chemicals
- Polymer Production
• Industry Solutions
- Pulp & Paper
- Semiconductor Industries
Technical Facts
Measuring quantitiesRefractive index and refractive index at standard temperature, fluid temperature, concentration g/l, mass and vol.%, density and density at standard temperature, scale values for example °Brix and °API, additional quantities programmable
Measurement rangenD: 1.3 ...1.7, °Brix: 0 ...100 Measurement accuracynD: 0.0002 (corresponds to: 0.1 °Brix, 0.1 w%) RepeatabilitynD: 0.00002 (corresponds to: 0.01 °Brix, 0.01 w%) Operating temp. (media)- 20 °C ... (+ 130 °C) + 150 °C Fluid pressurePN 10, PN 16, on request PN 40 (depending on process connection)
Degree of protectionSensor R500: IP67, ATEX (IECEx) zone 0,1,2
Transmitter R721: aluminium or stainless steel enclosure, IP66, ATEX (IECEx) zone 2
Wetted parts, materialsStainless steel 316Ti (1.4571) Housing materialStainless steel 304 (1.4301) Process connectionDIN/ANSI flange, sight glass fitting, proprietary FLEXIM flow cell Additional NotesPTFE Chemical Design variant: Wetted parts, materials: PTFE carbon-fiber reinforced bulk material
관리자 2021.02.04
The concentration analysis of liquid media is one of the most critical parameters for a proper process and quality control within the Chemical Industry.
By measuring the refractive index, concentration levels of many media consumed or created within the chemical and textile fiber industry, such as solvents, acids, caustics as well as other intermediate and end products, can accurately be monitored and a continuous quality control be assured.
The chemical design variant of the process refractometer PIOX R721 R is offered as a fully stainless steel design variant with all wetted materials made out of grade 316 Ti / 1.4571 steel.
When dealing with highly corrosive media, such as hydrochloric, strong sulfuric or hydroflouric acid, PIOX R is also available as a special carbon reinforced PTFE design variant offering an unrivalled corrosion resistance, long term stability and reliability in such harsh environments.
Both designs are highly durable against any corrosive and toxic media due to their internal FFKM gaskets, the media and scratch resistant sapphire optics as well as the complete separation of the sensorhead from the electronics compartment.
Being ATEX Zone 0/1 certified and available with long and short sensorheads that can be integrated into the process via DIN / ANSI flange or the proprietary FLEXIM flow cell, PIOX R721 is the ideal process analytical technology for a wide array of liquid media within the chemical industry.
Advantages
• Patented transmitted light measurement principle - offering completely drift free, precise and long term stable measurements
• Highly accurate optical process technology making costly laboratory tests obsolete
• No flow velocity needed - as known from conventional technologies
• Independent in regard to gas bubbles and turbidity as well as the media‘s viscosity
• Internal self diagnostic tools for predictive and low maintenance efforts
Advantages
• Oil & Gas
- Underground Gas Storage & Processing
- Upstream / Offshore Solutions
• Chemical Industry
- Base & Intermediate Chemicals
- Polymer Production
• Industry Solutions
- Pulp & Paper
- Semiconductor Industries
Technical Facts
Measuring quantitiesRefractive index and refractive index at standard temperature, fluid temperature, concentration g/l, mass and vol.%, density and density at standard temperature, scale values for example °Brix and °API, additional quantities programmable
Measurement rangenD: 1.3 ...1.7, °Brix: 0 ...100 Measurement accuracynD: 0.0002 (corresponds to: 0.1 °Brix, 0.1 w%) RepeatabilitynD: 0.00002 (corresponds to: 0.01 °Brix, 0.01 w%) Operating temp. (media)- 20 °C ... (+ 130 °C) + 150 °C Fluid pressurePN 10, PN 16, on request PN 40 (depending on process connection)
Degree of protectionSensor R500: IP67, ATEX (IECEx) zone 0,1,2
Transmitter R721: aluminium or stainless steel enclosure, IP66, ATEX (IECEx) zone 2
Wetted parts, materialsStainless steel 316Ti (1.4571) Housing materialStainless steel 304 (1.4301) Process connectionDIN/ANSI flange, sight glass fitting, proprietary FLEXIM flow cell Additional NotesPTFE Chemical Design variant: Wetted parts, materials: PTFE carbon-fiber reinforced bulk material
관리자 2021.02.04
10
Portable Ultrasonic Flow Meter (FLUXUS G601)
The Portable Gas flow meter
Portable gas flow metering without compromises
The FLUXUS G601 portable gas flow meter measures the flow of virtually any gas using FLEXIM's proven transit-time correlation technique.The ultrasonic transducers are simply clamped onto the outside of the pipe, thus no cutting into the pipe or process interruption is required for installation.
The FLUXUS G601 portable gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe. It is the ideal tool for servicing and maintenance activities, the control and auditing of measurement points not covered by permanent meters, or even the temporary replacement of permanently installed gas flow meters.
Though featuring an ergonomic design, which offers simple handling and maximum ease of use, the G601 was designed to easily withstand rough industrial environments. Besides its sturdy housing, the G601 portable gas flow meter features stable and precise push-pull transducer connectors with the cables themselves being steel armored to prevent breaking or rupturing during daily work.
The FLUXUS G601 gas flow meter offers maximum flexibility
With its Li-Ion battery, the G601 allows for up to 14 hours of autonomous measurement. Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducer calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are reduced and precise, long-term stable results are provided.
The portable gas flow meter can be applied at inner pipe diameters ranging from 6 mm up to 2100 mm (no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 100°C. Moreover, the measurement system is independent of the pressure inside the pipe.
With two measurement channels, the FLUXUS G601 portable gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.
Additionally the G601 can also be used for flow measurement of virtually any liquid media. Fur further information please consult the Technical Specifications of the F601 portable flow meter.
Advantages
• Non-invasive flow measurement for precise bi-directional, highly dynamic operational and standard volume flow
• Portable, easy-to-use gas flow meter with 2 flow channels, multiple inputs/outputs and an integrated data logger with a serial interface
• Automatic loading of calibration data and transducer detection reducing set-up times and providing precise, long-term stable results
• Li-Ion battery providing up to 14 hours of remote measurement operation
• Highly Accurate due to matched and paired as well as temperature compensated transducers
• Transducers available for a wide range of inner pipe diameters (7 mm... 1600 mm)
• Proven clamp-on technology, transducers resistant to dust and humidity
• Probe for wall thickness measurement available
• Water and dust-tight; resistant against oil, many liquids and dirt
• Robust, water-tight (IP67 ) transport case with comprehensive accessories
• QuickFix for fast mounting of the flow transmitter in difficult conditions
Applications
• Chemical Industry - Infrastructure and Feedstock Flows
• Industry Solutions - Semiconductor Industries
Technical Facts
Measurement uncertainty
(volumetric flow rate) ± 1...3 % of reading ±0.005 m/sRepeatability0.15 % of reading ±0.005 m/sFlow velocity range0.01...35 m/s, depending on pipe diameterEx zone transmitteronly safe areaPower supplyLi-ION 7.2V/6.2Ah Operat. time >25hAvailable transducerShear wave/Lamb wavefor Ex zones---for pipe sizes range7mm ... 1600mmfor temperature range-40°C ... +200°C Outputs4-20mA active/passive
pulse/frequency/binary InputsPt100/Pt1000
4-20mA passiveDigital communicationModbus RTU Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2021.02.04
Portable gas flow metering without compromises
The FLUXUS G601 portable gas flow meter measures the flow of virtually any gas using FLEXIM's proven transit-time correlation technique.The ultrasonic transducers are simply clamped onto the outside of the pipe, thus no cutting into the pipe or process interruption is required for installation.
The FLUXUS G601 portable gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe. It is the ideal tool for servicing and maintenance activities, the control and auditing of measurement points not covered by permanent meters, or even the temporary replacement of permanently installed gas flow meters.
Though featuring an ergonomic design, which offers simple handling and maximum ease of use, the G601 was designed to easily withstand rough industrial environments. Besides its sturdy housing, the G601 portable gas flow meter features stable and precise push-pull transducer connectors with the cables themselves being steel armored to prevent breaking or rupturing during daily work.
The FLUXUS G601 gas flow meter offers maximum flexibility
With its Li-Ion battery, the G601 allows for up to 14 hours of autonomous measurement. Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducer calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are reduced and precise, long-term stable results are provided.
The portable gas flow meter can be applied at inner pipe diameters ranging from 6 mm up to 2100 mm (no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 100°C. Moreover, the measurement system is independent of the pressure inside the pipe.
With two measurement channels, the FLUXUS G601 portable gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.
Additionally the G601 can also be used for flow measurement of virtually any liquid media. Fur further information please consult the Technical Specifications of the F601 portable flow meter.
Advantages
• Non-invasive flow measurement for precise bi-directional, highly dynamic operational and standard volume flow
• Portable, easy-to-use gas flow meter with 2 flow channels, multiple inputs/outputs and an integrated data logger with a serial interface
• Automatic loading of calibration data and transducer detection reducing set-up times and providing precise, long-term stable results
• Li-Ion battery providing up to 14 hours of remote measurement operation
• Highly Accurate due to matched and paired as well as temperature compensated transducers
• Transducers available for a wide range of inner pipe diameters (7 mm... 1600 mm)
• Proven clamp-on technology, transducers resistant to dust and humidity
• Probe for wall thickness measurement available
• Water and dust-tight; resistant against oil, many liquids and dirt
• Robust, water-tight (IP67 ) transport case with comprehensive accessories
• QuickFix for fast mounting of the flow transmitter in difficult conditions
Applications
• Chemical Industry - Infrastructure and Feedstock Flows
• Industry Solutions - Semiconductor Industries
Technical Facts
Measurement uncertainty
(volumetric flow rate) ± 1...3 % of reading ±0.005 m/sRepeatability0.15 % of reading ±0.005 m/sFlow velocity range0.01...35 m/s, depending on pipe diameterEx zone transmitteronly safe areaPower supplyLi-ION 7.2V/6.2Ah Operat. time >25hAvailable transducerShear wave/Lamb wavefor Ex zones---for pipe sizes range7mm ... 1600mmfor temperature range-40°C ... +200°C Outputs4-20mA active/passive
pulse/frequency/binary InputsPt100/Pt1000
4-20mA passiveDigital communicationModbus RTU Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2021.02.04
9
Ultrasonic Clamp-on Flow Measurement of Liquids and Gases (FLUXUS® F/G80X)
Permanent Flow Meter for Hazardous Areas
The ultrasonic flow meter for operation in hazardous areas
The FLUXUS F809 is FLEXIM's dual channel ultrasonic clamp-on flow meter for bi-directional flow measurement of liquids in hazardous areas ( ATEX, IECEx Zone 1 and FM Class I, Div. 1 approved).
With its flameproof housing and the corrosion resistant transducers residing outside the pipe wall, but inside the rugged VARIOFIX C mounting fixture, ensuring a permanent contact pressure and high mechanical stability, the FLUXUS F809 series is perfectly suited for every demanding industrial application. The connection and electronic compartment of the FLUXUS F809 is hermetically sealed, so that the measurement system provides maximum operational reliability and safety.
Not only is the FLUXUS F809 rugged and reliable, it is precise. Thanks to carefully matched and temperature compensated transducers (fully ANSI / ASME MFC 5M compliant), the FLUXUS F809 offers an unmatched zero point stability and precise bi-directional flow measurement of virtually any liquid media - ranging from crude oil to refined products and chemical media - over an unlimited turndown range.
The FLUXUS F809 flow meter can be applied at inner pipe diameters ranging from 6 mm up to 12000mm (no limitations on pipe wall thickness or material) and media temperatures from -190°C up to +600°C (by usage of the high temperature mounting fixture WaveInjector).
With up to two measurement channels, the FLUXUS F809 flow meter can also be applied to difficult measurement points with non-ideal flow profiles. Even liquid streams with a high content of solids or gas bubbles are not a problem due to the innovative HybridTrek mode and the unique signal processing implemented into the flow computer.
Advantages
• Bi-directional flow measurement of liquids and gases in FM Class I, Div. 1 and ATEX / IECEx Zone 1 areas
• Very cost effective: No pipe works, No process shut-downs, Virtually maintenance-free
• Matched, paired and wet calibrated flow transducers (traceable certification to national standards)
• Excellent zero point stability and drift-free
• Wide turndown ratio
• Independent of pipe size, material, operating pressure, medium and temperature (from as low as -170 °C up to +600 °C)
• High tolerance to entrained solids and gases
• Free of wear, tear and abrasion
• Not prone to clogging or corrosion
• No pressure loss or source of potential leaks and fugitive emissions
Applications
• Oil & Gas - Refinery Solutions - Upstream / Offshore Solutions
• Chemical Industry - Base & Intermediate Chemicals - Infrastructure and Feedstock Flows - Polymer Production
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1 % of reading ±0.005 m/sRepeatability 0.15 % of reading ±0.005 m/sFlow velocity range0.01...25 m/sEx zone transmitterATEX/IECEx Zone 1
FM Class I - Div1Power supply100-230VAC, 24DCAvailable transducerShear Wavefor Ex zonesATEX/IECEx Zone 1
FM Class I - Div1for pipe sizes range10mm ... 6500mmfor temperature range-40°C ... +240°C / WI: -200°C ... +600°COutputs4-20mA active/passive
4-20mA HART active/passive
4-20mA passive intrinsic safety
pulse/frequency/binaryInputs---Digital communication---Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2021.02.04
The ultrasonic flow meter for operation in hazardous areas
The FLUXUS F809 is FLEXIM's dual channel ultrasonic clamp-on flow meter for bi-directional flow measurement of liquids in hazardous areas ( ATEX, IECEx Zone 1 and FM Class I, Div. 1 approved).
With its flameproof housing and the corrosion resistant transducers residing outside the pipe wall, but inside the rugged VARIOFIX C mounting fixture, ensuring a permanent contact pressure and high mechanical stability, the FLUXUS F809 series is perfectly suited for every demanding industrial application. The connection and electronic compartment of the FLUXUS F809 is hermetically sealed, so that the measurement system provides maximum operational reliability and safety.
Not only is the FLUXUS F809 rugged and reliable, it is precise. Thanks to carefully matched and temperature compensated transducers (fully ANSI / ASME MFC 5M compliant), the FLUXUS F809 offers an unmatched zero point stability and precise bi-directional flow measurement of virtually any liquid media - ranging from crude oil to refined products and chemical media - over an unlimited turndown range.
The FLUXUS F809 flow meter can be applied at inner pipe diameters ranging from 6 mm up to 12000mm (no limitations on pipe wall thickness or material) and media temperatures from -190°C up to +600°C (by usage of the high temperature mounting fixture WaveInjector).
With up to two measurement channels, the FLUXUS F809 flow meter can also be applied to difficult measurement points with non-ideal flow profiles. Even liquid streams with a high content of solids or gas bubbles are not a problem due to the innovative HybridTrek mode and the unique signal processing implemented into the flow computer.
Advantages
• Bi-directional flow measurement of liquids and gases in FM Class I, Div. 1 and ATEX / IECEx Zone 1 areas
• Very cost effective: No pipe works, No process shut-downs, Virtually maintenance-free
• Matched, paired and wet calibrated flow transducers (traceable certification to national standards)
• Excellent zero point stability and drift-free
• Wide turndown ratio
• Independent of pipe size, material, operating pressure, medium and temperature (from as low as -170 °C up to +600 °C)
• High tolerance to entrained solids and gases
• Free of wear, tear and abrasion
• Not prone to clogging or corrosion
• No pressure loss or source of potential leaks and fugitive emissions
Applications
• Oil & Gas - Refinery Solutions - Upstream / Offshore Solutions
• Chemical Industry - Base & Intermediate Chemicals - Infrastructure and Feedstock Flows - Polymer Production
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1 % of reading ±0.005 m/sRepeatability 0.15 % of reading ±0.005 m/sFlow velocity range0.01...25 m/sEx zone transmitterATEX/IECEx Zone 1
FM Class I - Div1Power supply100-230VAC, 24DCAvailable transducerShear Wavefor Ex zonesATEX/IECEx Zone 1
FM Class I - Div1for pipe sizes range10mm ... 6500mmfor temperature range-40°C ... +240°C / WI: -200°C ... +600°COutputs4-20mA active/passive
4-20mA HART active/passive
4-20mA passive intrinsic safety
pulse/frequency/binaryInputs---Digital communication---Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2021.02.04
8
Ultrasonic Flow Meter (FLUXUS XLF)
Non-invasive Flow Meter for Extremely Low Flow rates
Do you need to measure really low flows? Turn to FLUXUS XLF
FLUXUS XLF is FLEXIM‘s non-invasive metering system for the reproducible and long term reliable measurement of extremely low flow rates down to 3 l/h and below on line sizes ranging from 10 mm to 50 mm independent of the pipe wall thickness. As the flow sensors are mounted externally, there is no process interruption for installation.
Moreover, due their IP66 protection degree, ATEX / IECEx Zone 1 / 2 as well as FM Class I, Div. 1 / 2 approval and being completely made out of stainless steel (316L / 1.4404 grade), the measurement system is highly rugged and withstands even the harshest and most corrosive environmental conditions.
FLEXIM is the much more cost-effective and safer alternative for measuring extremely low flows of any liquid
The FLUXUS XLF is applicable on all pipe materials and wall thicknesses as well as independent of operating pressures.
In comparison to wetted instrumentation, the system does not suffer from mechanical stress or wear and tear by the medium and is thus not only much more cost efficient, but also offers significantely higher operational safety as the risk of leaks can completely be eliminated.
Its high accuracy and repeatability at extremely low flow velocities is achieved by carefully matched and temperature compensated transducers (acc. to ANSI/ASME MFC 5.1-2011), highly sensitive electronics and sophisticated internal signal processing as well as a highly precise and traceable wet flow calibration (according to NIST standards) at FLEXIM‘s low flow calibration facility.
Advantages
• No process shut-downs or interruption of supply
• No potential for leaks
• Completely maintenance free
• Accurate and highly repeatable measurement of extremely low flows
• Applicable to any pipe and any liquid media
• Rugged and hazardous area approved transducers and transmitters (ATEX / IECEx Zone 1/2, FM Class I, Div. 1/2)
• Matched transducers, advanced digital signal processing (DSP) and efficient algorithms ensure stable measurements at very low flows
Applications
• Oil & Gas
- Underground Gas Storage & Processing
- Upstream / Offshore Solutions
• Industry Solutions
- Marine
Technical Facts
Flow channels 1 Operating temperature of the transmitter-40 °C ... +60 °C Degree of protectionIP66 Functional Safety (acc. to IEC / DIN EN 61508)SIL2 Optional hazardous area classificationATEX / IECEx Zone 1 and 2, FM Class I, Div. 1 / 2 OutputsA variety of combinations are available from the following: current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
InputsMaximum 4, Available are: Temperature (PT 100 4-wire), current, voltage
Communication ProtocolHART or Foundation Fieldbus or ModBus RTU or RS485 or BACNet MS/TP
Media temperature-40 °C ... +200 °C Pipe diameter range10 mm ... 50 mm (independent of material and wall thickness)
Flow velocity range> 0,003 m/sec (at stable media temperatures flows as low as 0,001 m/sec can accurately be monitored)
Calibrated accuracy± 1,2% of reading, ± 0,01 / (N x ID) [m/s] N = number of soundpaths, ID = inner diameter in [inch]
관리자 2020.06.08
Do you need to measure really low flows? Turn to FLUXUS XLF
FLUXUS XLF is FLEXIM‘s non-invasive metering system for the reproducible and long term reliable measurement of extremely low flow rates down to 3 l/h and below on line sizes ranging from 10 mm to 50 mm independent of the pipe wall thickness. As the flow sensors are mounted externally, there is no process interruption for installation.
Moreover, due their IP66 protection degree, ATEX / IECEx Zone 1 / 2 as well as FM Class I, Div. 1 / 2 approval and being completely made out of stainless steel (316L / 1.4404 grade), the measurement system is highly rugged and withstands even the harshest and most corrosive environmental conditions.
FLEXIM is the much more cost-effective and safer alternative for measuring extremely low flows of any liquid
The FLUXUS XLF is applicable on all pipe materials and wall thicknesses as well as independent of operating pressures.
In comparison to wetted instrumentation, the system does not suffer from mechanical stress or wear and tear by the medium and is thus not only much more cost efficient, but also offers significantely higher operational safety as the risk of leaks can completely be eliminated.
Its high accuracy and repeatability at extremely low flow velocities is achieved by carefully matched and temperature compensated transducers (acc. to ANSI/ASME MFC 5.1-2011), highly sensitive electronics and sophisticated internal signal processing as well as a highly precise and traceable wet flow calibration (according to NIST standards) at FLEXIM‘s low flow calibration facility.
Advantages
• No process shut-downs or interruption of supply
• No potential for leaks
• Completely maintenance free
• Accurate and highly repeatable measurement of extremely low flows
• Applicable to any pipe and any liquid media
• Rugged and hazardous area approved transducers and transmitters (ATEX / IECEx Zone 1/2, FM Class I, Div. 1/2)
• Matched transducers, advanced digital signal processing (DSP) and efficient algorithms ensure stable measurements at very low flows
Applications
• Oil & Gas
- Underground Gas Storage & Processing
- Upstream / Offshore Solutions
• Industry Solutions
- Marine
Technical Facts
Flow channels 1 Operating temperature of the transmitter-40 °C ... +60 °C Degree of protectionIP66 Functional Safety (acc. to IEC / DIN EN 61508)SIL2 Optional hazardous area classificationATEX / IECEx Zone 1 and 2, FM Class I, Div. 1 / 2 OutputsA variety of combinations are available from the following: current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
InputsMaximum 4, Available are: Temperature (PT 100 4-wire), current, voltage
Communication ProtocolHART or Foundation Fieldbus or ModBus RTU or RS485 or BACNet MS/TP
Media temperature-40 °C ... +200 °C Pipe diameter range10 mm ... 50 mm (independent of material and wall thickness)
Flow velocity range> 0,003 m/sec (at stable media temperatures flows as low as 0,001 m/sec can accurately be monitored)
Calibrated accuracy± 1,2% of reading, ± 0,01 / (N x ID) [m/s] N = number of soundpaths, ID = inner diameter in [inch]
관리자 2020.06.08
7
Ultrasonic Flow Meter (FLUXUS SIL G)
Functional Safety with FLUXUS
Functional Safety approved Gas Flowmeter
The FLUXUS non-invasive ultrasonic gas flow meters have always been the first choice when it comes to maintaining accurate measurements in harsh conditions – e.g. during the flow measurement of highly pressurised, aggressive, toxic or highly explosive gaseous media.
FLUXUS measures from the safe side: From outside.
The clamp-on ultrasonic transducers are simply mounted on the outside of the pipe. Without any risk of leak and during ongoing operation. The ultrasonic measuring method doesn’t need any wetted devices, works independent of the pressure inside the pipe and is not subjected to mechanical stress which means it is practically wear-free.
As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk. On the other hand, the SIL 2 certification of the FLUXUS non-invasive flow meter includes the entire measuring system -the measuring transmitters and transducers.
The clamp-on ultrasonic transducers are simply mounted on the outside of the pipe. Without any risk of leak and during ongoing operation. The ultrasonic measuring method doesn’t need any wetted devices, works independent of the pressure inside the pipe and is not subjected to mechanical stress which means it is practically wear-free.
As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk. On the other hand, the SIL 2 certification of the FLUXUS non-invasive flow meter includes the entire measuring system -the measuring transmitters and transducers.
Safety without interruption.
The advantages of FLEXIMs non-invasive flow measurement technology pay off all the more over the entire lifecycle:
There is never any need to interfere with the pipeline system when carrying out periodic inspections. The self-diagnosis functions of the FLUXUS mean retests can be carried out easily to accurately assess the reliability and quality of the measurement. Even more detailed functional tests such as alarm tests or tests for monitoring compliance with measuring accuracy requirements never interfere with plant availability.
Advantages
Functional safety with FLUXUS
• Non-invasive measurement without media contact
- shortened prior-use method
• Simple retrofitting during ongoing operation
- ideal for a subsequent increase in safety
- ideal for maintaining the protective function should an inline measurement fail
• Comprehensive certification
- transducers, clamp device and electronics are part of the FMEDA
• Extremely wide range of applications
- transducers and measuring transmitters for the flow measurement of liquids and gases
• Straightforward retesting
- easy functional tests in no time at all
- convincing self-diagnosis functions
• Transparent evaluations
- publication of FMEDA report
- full information on certification procedures and scope
Technical Facts
FLUXUS G70X ATEX, IECEx Zone 2, FM Class I, Div. 1 approval (optional), IP66, aluminium or stainless steel housing variants
FLUXUS G80XATEX, IECEx Zone 1, FM Class I, Div. 1 approval, IP66, aluminium or stainless steel housing variants - suitable for offshore use
Measuring quantitiesvolume flow rate, mass flow rate, flow velocity
Operating temperature of the transmitter-10 °C to +60 °C Degree of protection Transducersup to IP68 Operating temperature of the transducers at pipe wall-40 °C to +100°C Flow velocity range0,01 to 35 m/s Pipe diameter range6 mm to 2100 mm (up to 35mm of pipe wall thickness) Measurement accuracy± 1 ... 3% of reading ± 0,01 m/s (dependend on application) Measurement accuracy
(field calibrated)± 0,5% of reading ± 0,01 m/s Repeatability0,15% of reading ± 0,01 m/s Data logger capacity>100 000 values: all quantities, summed measurings and diagnostics
Communication ProtocolModbus RTU Power supply100 to 240 V AC / 50 to 60 Hz or 20 to 32 V DC
관리자 2020.06.08
Functional Safety approved Gas Flowmeter
The FLUXUS non-invasive ultrasonic gas flow meters have always been the first choice when it comes to maintaining accurate measurements in harsh conditions – e.g. during the flow measurement of highly pressurised, aggressive, toxic or highly explosive gaseous media.
FLUXUS measures from the safe side: From outside.
The clamp-on ultrasonic transducers are simply mounted on the outside of the pipe. Without any risk of leak and during ongoing operation. The ultrasonic measuring method doesn’t need any wetted devices, works independent of the pressure inside the pipe and is not subjected to mechanical stress which means it is practically wear-free.
As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk. On the other hand, the SIL 2 certification of the FLUXUS non-invasive flow meter includes the entire measuring system -the measuring transmitters and transducers.
The clamp-on ultrasonic transducers are simply mounted on the outside of the pipe. Without any risk of leak and during ongoing operation. The ultrasonic measuring method doesn’t need any wetted devices, works independent of the pressure inside the pipe and is not subjected to mechanical stress which means it is practically wear-free.
As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk. On the other hand, the SIL 2 certification of the FLUXUS non-invasive flow meter includes the entire measuring system -the measuring transmitters and transducers.
Safety without interruption.
The advantages of FLEXIMs non-invasive flow measurement technology pay off all the more over the entire lifecycle:
There is never any need to interfere with the pipeline system when carrying out periodic inspections. The self-diagnosis functions of the FLUXUS mean retests can be carried out easily to accurately assess the reliability and quality of the measurement. Even more detailed functional tests such as alarm tests or tests for monitoring compliance with measuring accuracy requirements never interfere with plant availability.
Advantages
Functional safety with FLUXUS
• Non-invasive measurement without media contact
- shortened prior-use method
• Simple retrofitting during ongoing operation
- ideal for a subsequent increase in safety
- ideal for maintaining the protective function should an inline measurement fail
• Comprehensive certification
- transducers, clamp device and electronics are part of the FMEDA
• Extremely wide range of applications
- transducers and measuring transmitters for the flow measurement of liquids and gases
• Straightforward retesting
- easy functional tests in no time at all
- convincing self-diagnosis functions
• Transparent evaluations
- publication of FMEDA report
- full information on certification procedures and scope
Technical Facts
FLUXUS G70X ATEX, IECEx Zone 2, FM Class I, Div. 1 approval (optional), IP66, aluminium or stainless steel housing variants
FLUXUS G80XATEX, IECEx Zone 1, FM Class I, Div. 1 approval, IP66, aluminium or stainless steel housing variants - suitable for offshore use
Measuring quantitiesvolume flow rate, mass flow rate, flow velocity
Operating temperature of the transmitter-10 °C to +60 °C Degree of protection Transducersup to IP68 Operating temperature of the transducers at pipe wall-40 °C to +100°C Flow velocity range0,01 to 35 m/s Pipe diameter range6 mm to 2100 mm (up to 35mm of pipe wall thickness) Measurement accuracy± 1 ... 3% of reading ± 0,01 m/s (dependend on application) Measurement accuracy
(field calibrated)± 0,5% of reading ± 0,01 m/s Repeatability0,15% of reading ± 0,01 m/s Data logger capacity>100 000 values: all quantities, summed measurings and diagnostics
Communication ProtocolModbus RTU Power supply100 to 240 V AC / 50 to 60 Hz or 20 to 32 V DC
관리자 2020.06.08
6
Ultrasonic Flow Meter (FLUXUS SIL F)
Functional Safety with FLUXUS
FLUXUS SIL - Non-invasive Fuctional Safety approved Flowmeter
The FLUXUS non-invasive ultrasonic flow meters have always been the first choice when it comes to maintaining accurate measurements in harsh conditions – e.g. during the flow measurement of aggressive, toxic or highly explosive media, at high temperatures or high pressure.
FLUXUS measures from the safe side: From outside.
The clamp-on ultrasonic transducers are simply mounted on the outside of the pipe. Without any risk of leak and during ongoing operation. The ultrasonic measuring method doesn’t need any wetted devices, does not pose any risk of clogging and is not subjected to mechanical stress which means it is practically wear-free.
As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk. On the other hand, the SIL 2 certification of the FLUXUS non-invasive flow meter includes the entire measuring system -the measuring transmitters and transducers. It also includes the patented WaveInjector mounting fixture for extreme temperatures, allowing the non-invasive flow measurement at liquid temperatures from as low as -190 °C up to +650 °C. FLEXIM also offers special radiation-resistant transducers for use in the nuclear industry.
Safety without interruption.
The advantages of FLEXIMs non-invasive flow measurement technology pay off all the more over the entire lifecycle:
There is never any need to interfere with the pipeline system when carrying out periodic inspections. The self-diagnosis functions of the FLUXUS mean retests can be carried out easily to accurately assess the reliability and quality of the measurement. Even more detailed functional tests such as alarm tests or tests for monitoring compliance with measuring accuracy requirements never interfere with plant availability.
Advantages
Functional safety with FLUXUS
• Non-invasive measurement without media contact
- shortened prior-use method
• Simple retrofitting during ongoing operation
- ideal for a subsequent increase in safety
- ideal for maintaining the protective function should an inline measurement fail
• Comprehensive certification
- transducers, clamp device and electronics are part of the FMEDA
• Extremely wide range of applications
- transducers and measuring transmitters for the flow measurement of liquids and gases
- SIL certification also covers WaveInjector technology for the flow measurement of liquids at extreme temperatures of -190 °C to +650 °C
• Straightforward retesting
- easy functional tests in no time at all
- convincing self-diagnosis functions
• Transparent evaluations
- publication of FMEDA report
- full information on certification procedures and scope
Applications
• Chemical Industry
- Base & Intermediate Chemicals
Technical Facts
FLUXUS F70XATEX, IECEx Zone 2, FM Class I, Div. 1 approval (optional), IP66, aluminium or stainless steel housing variants
FLUXUS ADM8X27ATEX, IECEx Zone 1, FM Class I, Div. 1 approval, IP66, aluminium or stainless steel housing variants - suitable for offshore use
Measuring quantitiesvolume flow rate, mass flow rate, flow velocity
Operating temperature of the transmitter-10 °C to +60 °C Degree of protection Transducersup to IP68 Operating temperature of the transducers at pipe wall-40 °C to +200°C or
-190 °C to +650 °C in conjunction with WaveInjector mounting fixture Flow velocity range0,01 to 25 m/s Pipe diameter range6 mm to 6500 mm Measurement accuracy
(extended calibration)± 1,2% of reading ± 0,01 m/s Measurement accuracy
(field calibrated)± 0,5% of reading ± 0,01 m/s Repeatability0,15% of reading ± 0,01 m/s Data logger capacity>100 000 values: all quantities, summed measurings and diagnostics Communication ProtocolModbus RTU Power supply100 to 240 V AC / 50 to 60 Hz or 20 to 32 V DC
관리자 2020.06.08
FLUXUS SIL - Non-invasive Fuctional Safety approved Flowmeter
The FLUXUS non-invasive ultrasonic flow meters have always been the first choice when it comes to maintaining accurate measurements in harsh conditions – e.g. during the flow measurement of aggressive, toxic or highly explosive media, at high temperatures or high pressure.
FLUXUS measures from the safe side: From outside.
The clamp-on ultrasonic transducers are simply mounted on the outside of the pipe. Without any risk of leak and during ongoing operation. The ultrasonic measuring method doesn’t need any wetted devices, does not pose any risk of clogging and is not subjected to mechanical stress which means it is practically wear-free.
As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk. On the other hand, the SIL 2 certification of the FLUXUS non-invasive flow meter includes the entire measuring system -the measuring transmitters and transducers. It also includes the patented WaveInjector mounting fixture for extreme temperatures, allowing the non-invasive flow measurement at liquid temperatures from as low as -190 °C up to +650 °C. FLEXIM also offers special radiation-resistant transducers for use in the nuclear industry.
Safety without interruption.
The advantages of FLEXIMs non-invasive flow measurement technology pay off all the more over the entire lifecycle:
There is never any need to interfere with the pipeline system when carrying out periodic inspections. The self-diagnosis functions of the FLUXUS mean retests can be carried out easily to accurately assess the reliability and quality of the measurement. Even more detailed functional tests such as alarm tests or tests for monitoring compliance with measuring accuracy requirements never interfere with plant availability.
Advantages
Functional safety with FLUXUS
• Non-invasive measurement without media contact
- shortened prior-use method
• Simple retrofitting during ongoing operation
- ideal for a subsequent increase in safety
- ideal for maintaining the protective function should an inline measurement fail
• Comprehensive certification
- transducers, clamp device and electronics are part of the FMEDA
• Extremely wide range of applications
- transducers and measuring transmitters for the flow measurement of liquids and gases
- SIL certification also covers WaveInjector technology for the flow measurement of liquids at extreme temperatures of -190 °C to +650 °C
• Straightforward retesting
- easy functional tests in no time at all
- convincing self-diagnosis functions
• Transparent evaluations
- publication of FMEDA report
- full information on certification procedures and scope
Applications
• Chemical Industry
- Base & Intermediate Chemicals
Technical Facts
FLUXUS F70XATEX, IECEx Zone 2, FM Class I, Div. 1 approval (optional), IP66, aluminium or stainless steel housing variants
FLUXUS ADM8X27ATEX, IECEx Zone 1, FM Class I, Div. 1 approval, IP66, aluminium or stainless steel housing variants - suitable for offshore use
Measuring quantitiesvolume flow rate, mass flow rate, flow velocity
Operating temperature of the transmitter-10 °C to +60 °C Degree of protection Transducersup to IP68 Operating temperature of the transducers at pipe wall-40 °C to +200°C or
-190 °C to +650 °C in conjunction with WaveInjector mounting fixture Flow velocity range0,01 to 25 m/s Pipe diameter range6 mm to 6500 mm Measurement accuracy
(extended calibration)± 1,2% of reading ± 0,01 m/s Measurement accuracy
(field calibrated)± 0,5% of reading ± 0,01 m/s Repeatability0,15% of reading ± 0,01 m/s Data logger capacity>100 000 values: all quantities, summed measurings and diagnostics Communication ProtocolModbus RTU Power supply100 to 240 V AC / 50 to 60 Hz or 20 to 32 V DC
관리자 2020.06.08
5
Ultrasonic Flow Meter (FLUXUS G801)
The Ultrasonic Gas Flow Meter for Offshore Environments
The Offshore Gas Flow Meter
The FLUXUS G801 is the ideal ultrasonic gas flow meter for permanent installation in rough and hazardous offshore environments.
Similar in its technical features to the FLUXUS G800 gas flow meter, the especially robust FLUXUS G801 is completely seawater and sea spray resistent and especially designed for applications found on Oil & Gas extraction platforms offshore.
The flow meter is encased in a Stainless Steel housing and can be operated by a magnet pen without opening the housing. It is certified for usage in potentially explosive areas (ATEX (IECEx) Zone 1).
The FLUXUS G801 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, enclosed in the rugged stainless steel VARIOFIX C mounting fixture, the system does not suffer from wear, tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.
Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME regulations) the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducers calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are reduced and precise, long-term stable results are provided.
The gas flow meter can be applied at inner pipe diameters ranging from 6 mm up to 2100 mm (no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 100°C. Moreover, the measurement system is independent of the pressure inside the pipe.
With up to two measurement channels, the FLUXUS G801 permanent gas flow meter can also be applied to difficult measurement points, is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.
Advantages
• Non-intrusive clamp-on ultrasonic flow measurement - no need to cut or weld the pipe
• Highly cost efficient: No process shut-down for installation required, virtually no maintenance needed due to permanent coupling and optimal device protection
• For explicit usage in hazardous areas - ATEX and IECEx Zone 1 approved flow meter
• Exact and reliable bi-directional measurement of actual and standard volume flows of gases over a wide turndown ratio
• Stainless Steel (SS316) field enclosure and transducer housing as well as rugged mounting fixtures with steel armored cables - Seawater resistant and corrosion proof
• Highly zero point stable and drift free due to paired transducers and an integrated temperature compensation (ANSI/ASME compliant)
• Two transducer technologies - Lamb and Shear Waves - for the most accurate measurement on the market
• Operational safe and highly accurate measurement even at wet gas
• Automatic recognition of the connected transducers and calibration data - high ease-of-use and user menu intuivity
• Sophisticated diagnostic tools for optimal set-up and control of the measurement system
Applications
• Oil & Gas
- Upstream / Offshore Solutions
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1...3 % of reading ±0.005 m/s Repeatability0.15 % of reading ±0.005 m/s Flow velocity range0.01...35 m/s, depending on pipe diameter Ex zone transmitterATEX/IECEx Zone 1 Power supply100-230VAC, 24DC Available transducerShear wave/Lamb wave for Ex zonesATEX/IECEx Zone 1 for pipe sizes range7mm ... 1600mm for temperature range-40°C ... +240°C Outputs4-20mA active/passive
4-20mA HART active/passive
4-20mA passive intrinsic safety
pulse/frequency/binary Inputs--- Digital communicationModbus RTU Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2020.06.08
The Offshore Gas Flow Meter
The FLUXUS G801 is the ideal ultrasonic gas flow meter for permanent installation in rough and hazardous offshore environments.
Similar in its technical features to the FLUXUS G800 gas flow meter, the especially robust FLUXUS G801 is completely seawater and sea spray resistent and especially designed for applications found on Oil & Gas extraction platforms offshore.
The flow meter is encased in a Stainless Steel housing and can be operated by a magnet pen without opening the housing. It is certified for usage in potentially explosive areas (ATEX (IECEx) Zone 1).
The FLUXUS G801 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, enclosed in the rugged stainless steel VARIOFIX C mounting fixture, the system does not suffer from wear, tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.
Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME regulations) the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducers calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are reduced and precise, long-term stable results are provided.
The gas flow meter can be applied at inner pipe diameters ranging from 6 mm up to 2100 mm (no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 100°C. Moreover, the measurement system is independent of the pressure inside the pipe.
With up to two measurement channels, the FLUXUS G801 permanent gas flow meter can also be applied to difficult measurement points, is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.
Advantages
• Non-intrusive clamp-on ultrasonic flow measurement - no need to cut or weld the pipe
• Highly cost efficient: No process shut-down for installation required, virtually no maintenance needed due to permanent coupling and optimal device protection
• For explicit usage in hazardous areas - ATEX and IECEx Zone 1 approved flow meter
• Exact and reliable bi-directional measurement of actual and standard volume flows of gases over a wide turndown ratio
• Stainless Steel (SS316) field enclosure and transducer housing as well as rugged mounting fixtures with steel armored cables - Seawater resistant and corrosion proof
• Highly zero point stable and drift free due to paired transducers and an integrated temperature compensation (ANSI/ASME compliant)
• Two transducer technologies - Lamb and Shear Waves - for the most accurate measurement on the market
• Operational safe and highly accurate measurement even at wet gas
• Automatic recognition of the connected transducers and calibration data - high ease-of-use and user menu intuivity
• Sophisticated diagnostic tools for optimal set-up and control of the measurement system
Applications
• Oil & Gas
- Upstream / Offshore Solutions
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1...3 % of reading ±0.005 m/s Repeatability0.15 % of reading ±0.005 m/s Flow velocity range0.01...35 m/s, depending on pipe diameter Ex zone transmitterATEX/IECEx Zone 1 Power supply100-230VAC, 24DC Available transducerShear wave/Lamb wave for Ex zonesATEX/IECEx Zone 1 for pipe sizes range7mm ... 1600mm for temperature range-40°C ... +240°C Outputs4-20mA active/passive
4-20mA HART active/passive
4-20mA passive intrinsic safety
pulse/frequency/binary Inputs--- Digital communicationModbus RTU Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2020.06.08
4
Ultrasonic Flow Meter (FLUXUS G706)
4-Beams for unrivalled Precision, Reliability and Repeatability
The FLUXUS G706 combines highest precision with the advantages of non-invasive ultrasonic gas flow measurement.
With its 4 beams, in reflect mode providing 8 paths through the gaseous medium, the meter averages the result of up to 4 planes. This arrangement averages out cross-flow profile disturbances and achieves the optimum non-invasive compensation. On longer straight runs, the 4-Beam meter achieves outstanding accuracy performance due to the individually averaged path effects and can thus be used for redundancy measurements of custody transfer meters or leak detection.
Temperature compensated transducers, unique digital signal processing with superior noise suppression combined with a highly rugged design care for an unrivalled degree of reliabilialy, durability and accuracy - ensuring perfect operation of the system under the harshest field conditions and makes it even suitable for installations buried in the ground (IP68 rated).
Custody Transfer Accuracy
The G706 is capable of accuracy in the Custody Transfer class. Clamp-on meters installed will contain some uncertainty due to pipe uncertainties and pipe geometry. These can be minimized with careful installation, precise pipe wall measurements and especially based on the effects of the multiple 4-channel measurement of the G706. While installed “out of box” custody transfer accuracy is not possible, in many pipeline services like check-metering, leak detection and others, it can be possible to calibrate the meter in-situ to achieve Custody class accuracy (proven by industry independent Calibration Facilities - test reports are available upon request).
AdvantagesEasy installation without process outagesWhen creating a new flow measurement point, a significant part of the costs are incurred by the installation work (line shut-down, pipe cutting, pipe flushing, etc.). These costs are significantly reduced using the F706 clamp-on technology that requires zero impact on pipe integrity while commissioning.
• Highly Economical: No heavy equipment necessary for installation, thus being the ideal solution for remote locations, or poorly accessible areas.• 100% plant availability: The non-invasive measurement technology does not require any process shut-downs - neither for installation nor for any potential maintenance efforts• Extremely low maintenance – virtually zero maintenance due to use of solid couplant pads instead of high maintenance gels• Safety: The F706 clamp-on meter does not add any leakage risk. It also does not require any flanges or gaskest
Laboratory Accuracy under Field ConditionsHigh accuracy and proven laboratory performance under reference conditions is one task. Accuracy under field conditions is quite another thing:
• FLEXIM‘s transducers automatically compensate for ambient temperature changes – according to ANSI/ASME MFC-5.1-2011. This ensures no false measurement readings during temperature swings (day / night)• FLEXIM‘s transducers are carefully paired according to their individual properties. This process lays the foundation for superior accuracies over a wide temperature and application range. It also ensures a negligible zero offset and facilitates the measurement of very low flow rates. There is no need for zeroing, or programmed “automatic zero” workarounds.• FLEXIM‘s transducers are all individually factory calibrated, with storage of the calibration data on a “Sensprom”chip. The calibrated transmitter automatically reads the individual calibration data, avoiding potential errors and making transducer exchanges easy.
For FLEXIM, accuracy is a topic we take seriously. FLEXIM‘s specified installed-accuracy claims can seem conservative but we firmly believe that clients expect us to over-perform rather than disappoint. Ask us, if you want to learn more about the total measurement uncertainty for your specific application.
Applications
• Oil & Gas
- Oil & Gas Storage and Distribution
- Underground Gas Storage & Processing
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1...3 % of reading ±0.005 m/s Repeatability0.15 % of reading ±0.005 m/s Flow velocity range0.01...35 m/s, depending on pipe diameter Ex zone transmitterATEX/IECEx Zone 2, FM Class I /Div 2 Power supply100-230VAC, 24DC, 12DC Available transducerShear wave/Lamb wave for Ex zonesATEX/IECEx Zone 1/Zone 2
FM Class I - Div2 for pipe sizes range7mm ... 1600mm for temperature range-40°C ... +240°C / WI: -200°C ... +600°C Outputs4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary InputsPt100/Pt1000
4-20mA active/passive
Binary input Digital communicationModbus RTU
Foundation Fieldbus
관리자 2020.06.08
The FLUXUS G706 combines highest precision with the advantages of non-invasive ultrasonic gas flow measurement.
With its 4 beams, in reflect mode providing 8 paths through the gaseous medium, the meter averages the result of up to 4 planes. This arrangement averages out cross-flow profile disturbances and achieves the optimum non-invasive compensation. On longer straight runs, the 4-Beam meter achieves outstanding accuracy performance due to the individually averaged path effects and can thus be used for redundancy measurements of custody transfer meters or leak detection.
Temperature compensated transducers, unique digital signal processing with superior noise suppression combined with a highly rugged design care for an unrivalled degree of reliabilialy, durability and accuracy - ensuring perfect operation of the system under the harshest field conditions and makes it even suitable for installations buried in the ground (IP68 rated).
Custody Transfer Accuracy
The G706 is capable of accuracy in the Custody Transfer class. Clamp-on meters installed will contain some uncertainty due to pipe uncertainties and pipe geometry. These can be minimized with careful installation, precise pipe wall measurements and especially based on the effects of the multiple 4-channel measurement of the G706. While installed “out of box” custody transfer accuracy is not possible, in many pipeline services like check-metering, leak detection and others, it can be possible to calibrate the meter in-situ to achieve Custody class accuracy (proven by industry independent Calibration Facilities - test reports are available upon request).
AdvantagesEasy installation without process outagesWhen creating a new flow measurement point, a significant part of the costs are incurred by the installation work (line shut-down, pipe cutting, pipe flushing, etc.). These costs are significantly reduced using the F706 clamp-on technology that requires zero impact on pipe integrity while commissioning.
• Highly Economical: No heavy equipment necessary for installation, thus being the ideal solution for remote locations, or poorly accessible areas.• 100% plant availability: The non-invasive measurement technology does not require any process shut-downs - neither for installation nor for any potential maintenance efforts• Extremely low maintenance – virtually zero maintenance due to use of solid couplant pads instead of high maintenance gels• Safety: The F706 clamp-on meter does not add any leakage risk. It also does not require any flanges or gaskest
Laboratory Accuracy under Field ConditionsHigh accuracy and proven laboratory performance under reference conditions is one task. Accuracy under field conditions is quite another thing:
• FLEXIM‘s transducers automatically compensate for ambient temperature changes – according to ANSI/ASME MFC-5.1-2011. This ensures no false measurement readings during temperature swings (day / night)• FLEXIM‘s transducers are carefully paired according to their individual properties. This process lays the foundation for superior accuracies over a wide temperature and application range. It also ensures a negligible zero offset and facilitates the measurement of very low flow rates. There is no need for zeroing, or programmed “automatic zero” workarounds.• FLEXIM‘s transducers are all individually factory calibrated, with storage of the calibration data on a “Sensprom”chip. The calibrated transmitter automatically reads the individual calibration data, avoiding potential errors and making transducer exchanges easy.
For FLEXIM, accuracy is a topic we take seriously. FLEXIM‘s specified installed-accuracy claims can seem conservative but we firmly believe that clients expect us to over-perform rather than disappoint. Ask us, if you want to learn more about the total measurement uncertainty for your specific application.
Applications
• Oil & Gas
- Oil & Gas Storage and Distribution
- Underground Gas Storage & Processing
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1...3 % of reading ±0.005 m/s Repeatability0.15 % of reading ±0.005 m/s Flow velocity range0.01...35 m/s, depending on pipe diameter Ex zone transmitterATEX/IECEx Zone 2, FM Class I /Div 2 Power supply100-230VAC, 24DC, 12DC Available transducerShear wave/Lamb wave for Ex zonesATEX/IECEx Zone 1/Zone 2
FM Class I - Div2 for pipe sizes range7mm ... 1600mm for temperature range-40°C ... +240°C / WI: -200°C ... +600°C Outputs4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary InputsPt100/Pt1000
4-20mA active/passive
Binary input Digital communicationModbus RTU
Foundation Fieldbus
관리자 2020.06.08
3
Ultrasonic Standard Volume Flow Meter (FLUXUS H721)
Clamp-on Ultrasonic Standard Volume Flow Measurement and API Determination of Hydrocarbons
FLUXUS H721 is FLEXIM’s flow and analytical measuring system for the hydrocarbon processing industry (HPI). It combines highly precise non-invasive measurement of volume flow and sound speed with sophisticated calculation features. The transmitter’s internal HPI computer calculates API gravity, operational density, density at base conditions and kinematic viscosity. Temperature and pressure compensation according to industry standards such as ASTM1250, GPA TP25 and D4311 allows for precise standard volume flow measurement of liquid hydrocarbons.
FLUXUS H721 is equipped with a database for a wide range of applications from light hydrocarbons to crude oils/refined products to heavy hydrocarbons. Application-specific parameterisation is easily possible via an editable table on the transmitter with liquid names and specific properties (density, API).
Typical applications of FLUXUS H721 are e.g. monitoring of pipeline integrity, product identification in tank farms, quality check measurements and verification or temporary replacement of stationary measuring devices.
Advantages
Cutting-edge Features of FLEXIM's ultrasonic non-intrusive flow measurement
• Automatic Fluid Identification and Interface Detection
• Bi-directional flow metering
• Superior temperature stability - No zero drift
• Certified and traceable Multi-Point wet flow calibration
• Robust “Fit for Purpose” Flexibility and Stability using PERMALOK mounting fixtures
• Operational capabilities from –40 °C up to +200 °C
• Extremely high turndown range - capability of measuring at very low flow rates
Applications
• Oil & Gas
- Oil & Gas Storage and Distribution
• Industry Solutions
- Marine
Technical Facts
Measuring quantities • flow: operating volumetric flow rate, standard volumetric flow rate according to ASTM 1250/TP25/4311, flow velocity, mass flow rate • HPI: API gravity, density, normalised density• interface detection: slope of the HPI physical quantities• fluid detection: according to fluid table Measurement uncertainty
(volumetric flow rate) ±1 % of reading ±0.005 m/s Transit time (HPI functions)repeatable:
1/(50 • fα) ±10-4 • tabsolute:
1/(5 • fα) ±10-4 • t
fα – transducer frequency
t – total transit time e.g. for transducers with transducer frequency M (fα = 1 MHz):
repeatable: 20 ns ±10-4 . t
absolute: 200 ns ±10-4 . t Explosion protectionTransmitter:
ATEX/IECEx zone 2
Transducers:
ATEX/IECEx Zone 2, FM Class I /Div 2 Power supply100 ... 230 V AC / 50 ... 60 Hz
12 / 24 V DC Outputs4 - 20 mA active
4- 20 mA HART active / passive
pulse / frequency / binary InputsPt100 / Pt1000
4 - 20 mA active / passive Digital communicationModbus RTU/TCP
HART
Profibus PA
Foundation Fieldbus Pipe diameter range6 mm ... 6500 mm Temperature range (pipe wall)-40 °C ... +240 °C Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2020.06.05
FLUXUS H721 is FLEXIM’s flow and analytical measuring system for the hydrocarbon processing industry (HPI). It combines highly precise non-invasive measurement of volume flow and sound speed with sophisticated calculation features. The transmitter’s internal HPI computer calculates API gravity, operational density, density at base conditions and kinematic viscosity. Temperature and pressure compensation according to industry standards such as ASTM1250, GPA TP25 and D4311 allows for precise standard volume flow measurement of liquid hydrocarbons.
FLUXUS H721 is equipped with a database for a wide range of applications from light hydrocarbons to crude oils/refined products to heavy hydrocarbons. Application-specific parameterisation is easily possible via an editable table on the transmitter with liquid names and specific properties (density, API).
Typical applications of FLUXUS H721 are e.g. monitoring of pipeline integrity, product identification in tank farms, quality check measurements and verification or temporary replacement of stationary measuring devices.
Advantages
Cutting-edge Features of FLEXIM's ultrasonic non-intrusive flow measurement
• Automatic Fluid Identification and Interface Detection
• Bi-directional flow metering
• Superior temperature stability - No zero drift
• Certified and traceable Multi-Point wet flow calibration
• Robust “Fit for Purpose” Flexibility and Stability using PERMALOK mounting fixtures
• Operational capabilities from –40 °C up to +200 °C
• Extremely high turndown range - capability of measuring at very low flow rates
Applications
• Oil & Gas
- Oil & Gas Storage and Distribution
• Industry Solutions
- Marine
Technical Facts
Measuring quantities • flow: operating volumetric flow rate, standard volumetric flow rate according to ASTM 1250/TP25/4311, flow velocity, mass flow rate • HPI: API gravity, density, normalised density• interface detection: slope of the HPI physical quantities• fluid detection: according to fluid table Measurement uncertainty
(volumetric flow rate) ±1 % of reading ±0.005 m/s Transit time (HPI functions)repeatable:
1/(50 • fα) ±10-4 • tabsolute:
1/(5 • fα) ±10-4 • t
fα – transducer frequency
t – total transit time e.g. for transducers with transducer frequency M (fα = 1 MHz):
repeatable: 20 ns ±10-4 . t
absolute: 200 ns ±10-4 . t Explosion protectionTransmitter:
ATEX/IECEx zone 2
Transducers:
ATEX/IECEx Zone 2, FM Class I /Div 2 Power supply100 ... 230 V AC / 50 ... 60 Hz
12 / 24 V DC Outputs4 - 20 mA active
4- 20 mA HART active / passive
pulse / frequency / binary InputsPt100 / Pt1000
4 - 20 mA active / passive Digital communicationModbus RTU/TCP
HART
Profibus PA
Foundation Fieldbus Pipe diameter range6 mm ... 6500 mm Temperature range (pipe wall)-40 °C ... +240 °C Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2020.06.05
2
Portable Ultrasonic Flow Meter (FLUXUS G608)
The portable Flowmeter for Gases in Hazardous Areas
No More HOT Work Permits! Certified Portable Gas Flow Metering in Hazardous Areas
The FLUXUS G608 portable gas flow meter is based on the widely used, highly reliable and versatile G601, but has been specifically engineered for its use within hazardous areas and is covered by ATEX, IECEx and FM certification.
It is the ideal solution for gas flow measurement in potentially explosive areas, may it be for a temporary replacement of a stationary flow meter, check metering or service operations. Due to its certification, users are not anymore obliged to obtain a Hot Work Permit, making the access to ATEX, IECEx and FM Zones much easier and less time consuming.
Offering a high degree of flexibility, without compromising on Safety!
The extremely resistant carbon fiber housing, together with the rugged transducer design, ensures a high impact protection as well as resistance against oil, water and many other liquids. The G608 portable gas flow meter shares the same efficient battery management as the G601, offering over 14 hrs. of remote measurement time.
Moreover, the measurement system can be fully set-up in a few minutes due to the intuitive user guidance and the automatic transducer recognition. Its application range is unrivaled - from pipes as small as 6 mm up to 2100 mm inner diameter and temperatures ranging from -40°C to 100°C.
The G608 gas flow meter goes where other portable devices can't
Being equipped with two flow channels, multiple Inputs and an integrated data logger with a serial interface, the portable gas flow meter is designed for direct usage in demanding environments, such as in the Upstream, Midstream and Downstream area as well as in the chemical and processing industries.
As known from all FLEXIM flow meters, also the G608 features a highly precise bi-directional measurement at fast and even very slow gas flow rates over a wide dynamic measurement and pressure range and is not prone to temperature and zero drift, being fully compliant to ANSI/ASME regulations.
However, the G608 is not only safe, accurate and reliable, but also very compact and lightweight, offering the user to even carry the complete measuring system as personal luggage for offshore visits.
Additionally the G608 can also be used for flow measurement of virtually any liquid media. Fur further information please consult the Technical Specifications of the F608 portable flow meter.
Advantages
Extremely resistant
• High impact Carbon Fibre housing
• Rugged transducer design
• Designed for ATEX, IECEx and FM Zones, IP65
• Compact and very lightweight
Instantly in Service
• Direct access to hazardous areas
• Fast and easy set-up (less than 5 minutes)
• Automatic transducer recognition
• Intuitive user guidance
Highly Versatile
• Unrivaled application range
• Superior accuracy even with media containing solids and gases due to the HybridTrek-Mode
• Integrated high capacity Li-Ion battery (>14 hrs. of remote measuring)
Accurate and Reliable
• All transducers are wet calibrated
• High precision during high and low flow rates
• No temperature and zero drift
Applications
• Oil & Gas - Refinery Solutions - Upstream / Offshore Solutions - Oil & Gas Storage and Distribution - Underground Gas Storage & Processing - Onshore / Shale Oil & Gas Solutions
• Chemical Industry - Acid and Caustics Production - Polymer Production - Base & Intermediate Chemicals - Infrastructure and Feedstock Flows - Chlorine Alkali Electrolysis
• Industry Solutions - Food & Beverage
Technical Facts
Measurement uncertainty
(volumetric flow rate) ± 1...3 % of reading ±0.005 m/s
Repeatability0.15 % of reading ±0.005 m/sFlow velocity range0.01...35 m/s, depending on pipe diameterEx zone transmitterATEX/IECEx Zone 2Power supplyLi-ION 7.2V/6.2Ah Operat. time >25hAvailable transducerShear wave/Lamb wavefor Ex zonesATEX/IECEx Zone 1/Zone 2for pipe sizes range7mm ... 1100mmfor temperature range-40°C ... +200°COutputs4-20mA active/passive
pulse/frequency/binary InputsPt100/Pt1000Digital communication--- Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2020.06.05
No More HOT Work Permits! Certified Portable Gas Flow Metering in Hazardous Areas
The FLUXUS G608 portable gas flow meter is based on the widely used, highly reliable and versatile G601, but has been specifically engineered for its use within hazardous areas and is covered by ATEX, IECEx and FM certification.
It is the ideal solution for gas flow measurement in potentially explosive areas, may it be for a temporary replacement of a stationary flow meter, check metering or service operations. Due to its certification, users are not anymore obliged to obtain a Hot Work Permit, making the access to ATEX, IECEx and FM Zones much easier and less time consuming.
Offering a high degree of flexibility, without compromising on Safety!
The extremely resistant carbon fiber housing, together with the rugged transducer design, ensures a high impact protection as well as resistance against oil, water and many other liquids. The G608 portable gas flow meter shares the same efficient battery management as the G601, offering over 14 hrs. of remote measurement time.
Moreover, the measurement system can be fully set-up in a few minutes due to the intuitive user guidance and the automatic transducer recognition. Its application range is unrivaled - from pipes as small as 6 mm up to 2100 mm inner diameter and temperatures ranging from -40°C to 100°C.
The G608 gas flow meter goes where other portable devices can't
Being equipped with two flow channels, multiple Inputs and an integrated data logger with a serial interface, the portable gas flow meter is designed for direct usage in demanding environments, such as in the Upstream, Midstream and Downstream area as well as in the chemical and processing industries.
As known from all FLEXIM flow meters, also the G608 features a highly precise bi-directional measurement at fast and even very slow gas flow rates over a wide dynamic measurement and pressure range and is not prone to temperature and zero drift, being fully compliant to ANSI/ASME regulations.
However, the G608 is not only safe, accurate and reliable, but also very compact and lightweight, offering the user to even carry the complete measuring system as personal luggage for offshore visits.
Additionally the G608 can also be used for flow measurement of virtually any liquid media. Fur further information please consult the Technical Specifications of the F608 portable flow meter.
Advantages
Extremely resistant
• High impact Carbon Fibre housing
• Rugged transducer design
• Designed for ATEX, IECEx and FM Zones, IP65
• Compact and very lightweight
Instantly in Service
• Direct access to hazardous areas
• Fast and easy set-up (less than 5 minutes)
• Automatic transducer recognition
• Intuitive user guidance
Highly Versatile
• Unrivaled application range
• Superior accuracy even with media containing solids and gases due to the HybridTrek-Mode
• Integrated high capacity Li-Ion battery (>14 hrs. of remote measuring)
Accurate and Reliable
• All transducers are wet calibrated
• High precision during high and low flow rates
• No temperature and zero drift
Applications
• Oil & Gas - Refinery Solutions - Upstream / Offshore Solutions - Oil & Gas Storage and Distribution - Underground Gas Storage & Processing - Onshore / Shale Oil & Gas Solutions
• Chemical Industry - Acid and Caustics Production - Polymer Production - Base & Intermediate Chemicals - Infrastructure and Feedstock Flows - Chlorine Alkali Electrolysis
• Industry Solutions - Food & Beverage
Technical Facts
Measurement uncertainty
(volumetric flow rate) ± 1...3 % of reading ±0.005 m/s
Repeatability0.15 % of reading ±0.005 m/sFlow velocity range0.01...35 m/s, depending on pipe diameterEx zone transmitterATEX/IECEx Zone 2Power supplyLi-ION 7.2V/6.2Ah Operat. time >25hAvailable transducerShear wave/Lamb wavefor Ex zonesATEX/IECEx Zone 1/Zone 2for pipe sizes range7mm ... 1100mmfor temperature range-40°C ... +200°COutputs4-20mA active/passive
pulse/frequency/binary InputsPt100/Pt1000Digital communication--- Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2020.06.05
1
Liquid and Gas Flow Measurement (FLUXUS® F/G721)
Setting Standards in Clamp-on Ultrasonic Liquid Flow Measurement
The FLUXUS F721 is a technological breakthrough in the ultrasonic clamp-on volume and mass flow measurement of liquids.
With its state-of-the-art hardware design and powerful digital signal processing it surpasses any other non-intrusive ultrasonic flowmeter in terms of accuracy, reliability and versatility.
Highly sophisticated signal filters, faster than ever processing capacities and advanced measurement algorithms make the FLUXUS F721 liquid flow meter the standard setting measuring solution for any industrial application- even for the most challenging ones.
The meter adapts itself automatically to the respective measurement conditions and compensates for flow profile disturbances such as beam dispersal and structure-borne noise, allowing for even more precise and reliable measurements. Extreme fast measurement cycles enable precise real time monitoring of highly dynamic processes.
Pushing the Boundaries
The FLUXUS F721 offers non-intrusive flow measurement of virtually any kind of liquid, from the smallest tubing to the largest penstock, independent of the pressure inside the pipe and over a very large temperature range. Due to its advanced technology, the measurement is unaffected by solid or gaseous entrainments and distinguishes itself by its unrivalled turndown ratio: Even low flows down to only a few liters per hour can be recorded accurately.
Besides its advanced signal processing and evaluation technology, FLEXIM takes special care within the manufacturing process of the flow meter, ensuring highest precision and reliability. To achieve true zero point stability, FLEXIM carefully matches each ultrasonic transducer pair according to their individual characteristics. Due to unique transducer built-in temperature probes, the FLUXUS F721 automatically detects and compensates temperature differentials between pipe and transducer, ruling out measurement drift (ANSI/ASME MFC-5.1.-2011 regulations). Also, every transducer and transmitter is factory calibrated guaranteeing specified accuracies and ensuring highest traceability and flexibility.
Furthermore, the FLUXUS F721 shares all common advantages of our FLUXUS clamp-on flow meters in terms of ease of installation, non-existent maintenance efforts and unrivalled cost-efficiency. As the flowmeter of choice for a very wide range of applications in virtually any industrial sector, the FLUXUS F721 is available with two different enclosure types: aluminium for standard applications and stainless steel for operation in hazardous and highly corrosive environments (ATEX, IECEx Zone 2 and FMc Class I, Div. 2 certified).
Ready for Industry 4.0 The FLUXUS F721 comes with all common communication protocols: HART, Modbus, Foundation Fieldbus, Profibus PA, BACnet and M-Bus allow bidirectional field communication and online diagnostics. The FLUXUS F721 is also one step ahead in terms of user guidance and diagnostics. It can be easily set-up and configured via USB. Its Ethernet connectivity provides additional bidirectional communication capabilities.
Further value is added by the meters advanced selfmonitoring capabilities and the possibility of event driven data recording. The flow meter is permanently controlling the quality of the measurement. Such values, but also every other measurement data as well as externally fed in data, e.g. pressure and temperatues, can be chosen to trigger free defined meter functionalities. For instance, in case the quality of the measurement is falling below a predefined value, a temporary recording of high resolution measurement data can automatically be started. Such free configurable event based trigger functionality is not only perfectly suited for measurement diagnostics, but even more for the accurate monitoring of processes and especially the supervision and control of critical operations.
Applications
• Oil & Gas - Refinery Solutions - Onshore / Shale Oil & Gas Solutions - Underground Gas Storage & Processing - Upstream / Offshore Solutions - Oil & Gas Storage and Distribution
• Chemical Industry - Acid and Caustics Production - Base & Intermediate Chemicals - Fertilizer Plants - Infrastructure and Feedstock Flows - Polymer Production - Chlorine Alkali Electrolysis
• Industry Solutions - Pharmaceutical Industries - Pulp & Paper - Mining - Marine
• Power Industry - Hydroelectric power plants
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1 % of reading ±0.005 m/s Repeatability0.15 % of reading ±0.005 m/s Flow velocity range0.01...25 m/s Ex zone transmitterATEX/IECEx Zone 2, FM Class I /Div 2 Power supply100-230VAC, 24DC, 12DCAvailable transducer Shear Wave for Ex zonesATEX/IECEx Zone 1/Zone 2
FM Class I - Div2 for pipe sizes range6mm ... 6500mm for temperature range-40°C ... +240°C / WI: -200°C ... +600°C Outputs4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary InputsPt100/Pt1000
4-20mA active/passive
Binary input Digital communicationModbus RTU/TCP
BACnet MSTP/IP
M-Bus
Profibus PA
Foundation Fieldbus Additional InformationFor more detailed Information please download the Technical Specifications
관리자 2020.06.05
The FLUXUS F721 is a technological breakthrough in the ultrasonic clamp-on volume and mass flow measurement of liquids.
With its state-of-the-art hardware design and powerful digital signal processing it surpasses any other non-intrusive ultrasonic flowmeter in terms of accuracy, reliability and versatility.
Highly sophisticated signal filters, faster than ever processing capacities and advanced measurement algorithms make the FLUXUS F721 liquid flow meter the standard setting measuring solution for any industrial application- even for the most challenging ones.
The meter adapts itself automatically to the respective measurement conditions and compensates for flow profile disturbances such as beam dispersal and structure-borne noise, allowing for even more precise and reliable measurements. Extreme fast measurement cycles enable precise real time monitoring of highly dynamic processes.
Pushing the Boundaries
The FLUXUS F721 offers non-intrusive flow measurement of virtually any kind of liquid, from the smallest tubing to the largest penstock, independent of the pressure inside the pipe and over a very large temperature range. Due to its advanced technology, the measurement is unaffected by solid or gaseous entrainments and distinguishes itself by its unrivalled turndown ratio: Even low flows down to only a few liters per hour can be recorded accurately.
Besides its advanced signal processing and evaluation technology, FLEXIM takes special care within the manufacturing process of the flow meter, ensuring highest precision and reliability. To achieve true zero point stability, FLEXIM carefully matches each ultrasonic transducer pair according to their individual characteristics. Due to unique transducer built-in temperature probes, the FLUXUS F721 automatically detects and compensates temperature differentials between pipe and transducer, ruling out measurement drift (ANSI/ASME MFC-5.1.-2011 regulations). Also, every transducer and transmitter is factory calibrated guaranteeing specified accuracies and ensuring highest traceability and flexibility.
Furthermore, the FLUXUS F721 shares all common advantages of our FLUXUS clamp-on flow meters in terms of ease of installation, non-existent maintenance efforts and unrivalled cost-efficiency. As the flowmeter of choice for a very wide range of applications in virtually any industrial sector, the FLUXUS F721 is available with two different enclosure types: aluminium for standard applications and stainless steel for operation in hazardous and highly corrosive environments (ATEX, IECEx Zone 2 and FMc Class I, Div. 2 certified).
Ready for Industry 4.0 The FLUXUS F721 comes with all common communication protocols: HART, Modbus, Foundation Fieldbus, Profibus PA, BACnet and M-Bus allow bidirectional field communication and online diagnostics. The FLUXUS F721 is also one step ahead in terms of user guidance and diagnostics. It can be easily set-up and configured via USB. Its Ethernet connectivity provides additional bidirectional communication capabilities.
Further value is added by the meters advanced selfmonitoring capabilities and the possibility of event driven data recording. The flow meter is permanently controlling the quality of the measurement. Such values, but also every other measurement data as well as externally fed in data, e.g. pressure and temperatues, can be chosen to trigger free defined meter functionalities. For instance, in case the quality of the measurement is falling below a predefined value, a temporary recording of high resolution measurement data can automatically be started. Such free configurable event based trigger functionality is not only perfectly suited for measurement diagnostics, but even more for the accurate monitoring of processes and especially the supervision and control of critical operations.
Applications
• Oil & Gas - Refinery Solutions - Onshore / Shale Oil & Gas Solutions - Underground Gas Storage & Processing - Upstream / Offshore Solutions - Oil & Gas Storage and Distribution
• Chemical Industry - Acid and Caustics Production - Base & Intermediate Chemicals - Fertilizer Plants - Infrastructure and Feedstock Flows - Polymer Production - Chlorine Alkali Electrolysis
• Industry Solutions - Pharmaceutical Industries - Pulp & Paper - Mining - Marine
• Power Industry - Hydroelectric power plants
Technical Facts
Measurement uncertainty
(volumetric flow rate) ±1 % of reading ±0.005 m/s Repeatability0.15 % of reading ±0.005 m/s Flow velocity range0.01...25 m/s Ex zone transmitterATEX/IECEx Zone 2, FM Class I /Div 2 Power supply100-230VAC, 24DC, 12DCAvailable transducer Shear Wave for Ex zonesATEX/IECEx Zone 1/Zone 2
FM Class I - Div2 for pipe sizes range6mm ... 6500mm for temperature range-40°C ... +240°C / WI: -200°C ... +600°C Outputs4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary InputsPt100/Pt1000
4-20mA active/passive
Binary input Digital communicationModbus RTU/TCP
BACnet MSTP/IP
M-Bus
Profibus PA
Foundation Fieldbus Additional InformationFor more detailed Information please download the Technical Specifications