MY MENU
제목

Heavy duty portable ultrasonic water flow meter (FLUXUS F401)

작성자
관리자
작성일
2020.06.05
첨부파일1
추천수
0
조회수
490
내용

Heavy duty portable ultrasonic water flow meter


The FLUXUS F401 is the ideal flow meter for long-term measurement campaigns in the field. Depending on the programmed measurement interval the FLUXUS F401 can operate autonomously for several months. This makes it suitable for leak detection campaigns and hydraulic studies, where regular measurements are needed over a longer period of time.


The clamp-on ultrasonic system has been designed especially to meet the needs of the water and wastewater industries. The FLUXUS F401 is installed without process interruption and the installation can be completed within a few minutes. Thereafter, it delivers accurate and highly repeatable measurements that are not affected by drift. Due to its excellent low flow capability (down to 0.01 m/s), the FLUXUS F401 is ideally suited for monitoring drinking water networks, in which low flow velocities are common. The strong signal output and the noise suppression technology make it possible to use the FLUXUS F401 on very large pipes and challenging materials: Old and rusty steel, badly manufactured GRP or even armored concrete pipes (independent of lining and build-up inside the pipe) are not a metering challenge to the FLUXUS F401.


All parts of the FLUXUS F401 have been designed to ensure utmost robustness for regular heavy duty use in rough conditions. The metal sheathing of the transducer cable ends protects them against strong bending or cuts and ensures tangle-free operation. The six meter cable length of the IP68 transducers allows for the installation of the transducers even in deep manholes, whereby the transmitter can be placed in the upper part of the manhole. The transmitter is housed in a robust case and has IP67 protection.


All this makes the FLUXUS F401 the ideal companion for the daily work of water suppliers, hydrologists and engineering offices.




Advantages


• Several months battery-powered operation time


• Extremely robust design


• Ideal for long field campaigns


• Metal cable sheathing


• Permanent coupling pads


• IP68 transducers



Applications


• Water & Sewage


  - Potable Water Treatment


  - Water network monitoring and leak detection


  - Wastewater Treatment



Technical Facts


 Operating temperature of the transmitter

-10 °C ... 50 °C 

 Operating temperature of the transducers at pipe wall

-40 °C ... 100 °C 

 Degree of protection TransmitterIP67 
 Degree of protection TransducersIP68
 Outputs

1x Current, 1x Binary

 Communication InterfaceRS232 / USB (with adapter)
 Pipe diameter range40 mm ... 3 m
 Flow velocity range 0,01 ... 25 m/s
 Measurement accuracy±2.0 % of reading ±0,01 m/s
 Repeatability0.25 % of reading ±0,01 m/s
 Mediumwater with <6% gaseous or solid content by volume