MY MENU
제목

Mass Flow, Density and Concentration Metering (PIOX S)

작성자
관리자
작성일
2020.06.05
첨부파일1
조회수
985
내용

Mass Flow, Density and Concentration Measurement without media contact


PIOX S721 determines mass flow rate, concentration, density and other parameters by means of clamp-on ultrasonic transducers mounted on the outside of the pipe. The non-invasive acoustic technology is the system of choice when substances and processes place highest demands on safety and reliability.


Indestructible as a matter of principle


In a large number of binary media systems, the acoustic velocity is in a fixed proportion to concentration and density. PIOX S721 measures the acoustic velocity, thereby determining the density and concentration of the medium inside the pipe. By simultaneously recording the volume flow rate, PIOX S721 automatically calculates the mass flow rate.


Applications


• For virtually all pipe sizes and materials – regardless of whether it‘s steel, plastic, glass or special materials with coatings

• For temperatures up to 400 °C

• For almost all acids, caustics and a wide range of other toxic media

• For hazardous areas – transducers and transmitters are available in ATEX, IECEX and FM certified variants

• For 100% plant availability – the measurement point can be set up during ongoing operation



The ideal "Outsider"


 The PIOX S measuring system, composed of a transmitter and a pair of clamp-on transducers, precisely determines the sonic velocity of the medium based upon the ultrasonic transit-time measured between the two transducers.The clamp-on transducers are mounted on the outer surface of the pipe. As they are not in contact with the medium, the system is ideally suited for the measurement of chemically aggressive, corrosive, abrasive or ultra-pure media.


 PIOX S can be used to determine the concentration of high purity sulfuric acid, hydrofluoric acid, nitric acid or even ammonia gas used in fertilizer plants. Worries about the transducers chemical compatibility, contamination and sealing are a thing of the past.


 With the clamp-on technology, retrofitting of existing installations is very easy and can be done without cutting into the pipe and without any process interruption.










Applications


Precise and reliable


• Permanently stable measurement without any drift


• Accurate measurements at the lowest and highest flow velocities


• Independent of entrained solids or gas


• Continuous monitoring of measurement quality



Cost-effective and economical


• No plant shutdown for commissioning


• No special materials or bypass solutions required


• No early failure of measuring system


• Simultaneous determination of mass flow as well as concentration and density



Durable and long term stability


• No media contact, therefore no risk of corrosion


• No moving parts, no vibrations, no material fatigue


• No pressure limitations


• For harsh industrial environments



Safe and available


• Mounting of the measurement system outside of the pipe, no need for pipe modifications


• Maintenance-free measurement system


• No leakage risk



Applications


• Oil & Gas


  - Underground Gas Storage & Processing


  - Onshore / Shale Oil & Gas Solutions


• Chemical Industry


  - Acid and Caustics Production


  - Chlorine Alkali Electrolysis


  - Fertilizer Plants


• Industry Solutions


  - Pharmaceutical Industries


  - Pulp & Paper


  - Mining


  - Marine




Technical Facts


 Measurement uncertainty
(volumetric flow rate)

±1 % of reading ±0.005 m/s

 Repeatability0.15 % of reading ±0.005 m/s
 Flow velocity range

0.01...25 m/s

 
 Ex zone transmitter

ATEX/IECEx Zone 2, FM Class I /Div 2

 Power supply

100-230VAC, 24DC, 12DC

Available transducer 

Shear Wave

 for Ex zones

---

 for pipe sizes range

10mm ... 6500mm

 for temperature range

-40°C ... +240°C / WI: -200°C ... +600°C

 Outputs4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary 
 InputsPt100/Pt1000
4-20mA active/passive
Binary input
 Digital communication

Modbus RTU/TCP
BACnet MSTP/IP
Profibus PA
Foundation Fieldbus

 Additional Information

For more detailed Information please download the Technical Specifications